سوال:با سلام و خسته نباشید
ببخشید این تایمر زمان روشن و خاموش جدا دارد؟مثلا یک دقیقه روشن بعد خاموش و هر یک ساعت همینطور تکرار بشه(برای جوجه کشی)
ماژول کنترل دور موتور DC همراه با تایمر
01F032
موجودی این محصول به صورت موقت به پایان رسیده است.
DC motor positive and negative module automatic speed control timing delay limit H bridge / control 12 / 24V
Product information:
1: Model: YYH-2 can control the DC motor forward and reverse, speed, timing, limit and other functions in one, to meet more application needs.
2: Features: This product uses MOS tube H bridge circuit, excellent performance, input and output optocoupler isolation, the minimum can be 0.1 seconds to frequent switching, no noise, stepless speed, far more than relay contact control, relay contacts Life limit, and there are sound, poor sensitivity, frequent contact easy to burn the relay contact
3: low power consumption: 20ma or so, you can set the low power mode, standby current is less than 10ma
4: input voltage range and controllable power: Input voltage: DC6.2V ~ 28V output can control the current within 5A motor
5: time range: 0.1 seconds to 999 minutes any time adjustable
6: speed range: adjustable potentiometer, the speed from 0% to 100% stepless speed
7: Terminal port description:
IN1, IN2, IN3: Signal input (active low, negative trigger, NPN sensor can be connected)
DC-: power supply negative input (DC 6.2V ~ 28V wide voltage)
DC +: power positive input
M +, M-: output termination motor, regardless of positive and negative level
8: other common problems: A: all settings options can be automatically saved, set the contents of the power loss is not lost
B: can be frequently off, the performance is better than the relay, life than ordinary electromagnetic relay to long
9: Function Details:
P-11: jog: to signal 1, the motor is running, the signal 1 disappears, the motor stops; the signal 2 controls the reversal, the function is the same as 1
P-12: self-locking: to signal 1, the motor to keep forward, to the signal 3, the relay release; signal 2 control reversal, function with 1
P-13: to signal 1, forward to A time automatically stop; signal 2 control reverse, with the same function; signal self-locking
P-14: to signal 1, forward to A time automatically stop; signal 2 control reversal, function with 1; signal non-self-locking
P-15: signal 1 exceeds A time, forward rotation; signal 1 disappears, motor stops, signal 2 controls reversal, function same as 1; signal self-locking
P-16: signal 1 exceeds A time, forward rotation; signal 1 disappears, motor stops, signal 2 controls reverse, function is same 1; signal is not self-locking
P-21: After power-up, turn to A time, then reverse B time; forward and reverse cycle (with total time setting C, total time set to 0, infinite loop)
P-22: Conditional loop mode: A signal is activated P-21 cycle, no signal stop cycle
P-23: After power is on, turn to A time, wait for C time, reverse B time, wait for C time; infinite loop
P-24: CONDITION CIRCUIT MODE: There is signal to start P-23 cycle, no signal stop cycle
P-31: After power is turned on, it is stopped at time A and then reverses to B time to stop;
P-32: to signal 1, forward to A time release, and then reverse to B time to stop; then remain stopped
P-33: After power-up, go to time A, wait for C time, reverse B time stop, and then stop
P-34: to signal 1, forward to A time, wait for C time, reverse B time to stop, and then remain stopped
P-35: to the signal, is to go to A time to stop; give the signal, reverse to B time to stop;
P-36: to signal, forward to A time to stop; signal disappears, reverse to B time to stop;
Note: All functions inside: signal 3 is the emergency stop reset limit signal
10: key setting instructions: power display "----" that entered standby;
Press the first time K1, the screen shows: P-11: K2 and K3 adjust the main mode, K4 adjustment function
Press the second time K1, the screen shows: A001: K2 and K3 adjust the first time, K4 adjust the decimal point (time unit)
Press the third time K1, the screen shows: B001: K2 and K3 adjust the second time, K4 adjust the decimal point (time unit)
Press the fourth time K1, the screen shows: C001: K2 and K3 adjust the third time, K4 adjust the decimal point (time unit)
Press the fifth K1, display "----" that entered into the standby state;
Press K4 in standby mode to turn off / on display and switch low power mode
11: decimal point time unit description:
XX.X decimal point in ten, timing range: 0.1 seconds to 99.9 seconds
XXX no decimal point, timing range: 1 second to 999 seconds
XXX. Decimal points in the bit, timing range: 1 minute to 999 minutes
پاسخ:این تایمر برای جوجه کشی مناسب نیست.موفق باشید.