ماژول تایمر دارای ورودی تحریک 12 ولت دی سی
02F034
موجودی این محصول به صورت موقت به پایان رسیده است.
محصولات مشابه
-
ماژول تایمر 0 تا 60 ثانیه 12 ولت DC
1,050,000 ریال
-
ماژول کنترلر دما(ترموستات)W1701
720,000 ریال
-
ماژول ترموستات دیجیتال W1401 دارای نمایشگر و کلیدهای کنترلی
2,700,000 ریال
-
ماژول رله 5 ولت هشت کاناله با نشانگر LED
1,800,000 ریال
-
ماژول وای فای کنترلر با هسته esp8266
1,600,000 ریال
-
سنسور جریان آب Water Flow Sensor
1,600,000 ریال
-
سوئیچ جیوه ای 12 میلی متری
85,000 ریال
product description:
1: Model: YYC-2S 24 kinds of commonly used functions to meet the needs of more applications; can control the solenoid valve, pumps, motors, lights and other running freely
2: Input voltage: DC 12
3: Output power: can control within 5A or DC load or AC load
4: time range: 0.01 seconds to 999 minutes any time adjustable
5: Terminal port description:
1, DC +: input DC power positive
2, DC-: input DC power supply negative
3, IN +: positive signal input
4, IN-: signal input negative
5, NO: relay normally open interface, relay pull before the suspension, after the short connection with the COM
6, COM: relay common interface
7, NC: relay normally closed interface, the relay before the connection with the COM short, pull after the suspension
6: Function list:
P-11: Jog (to signal relay pull, signal disappearance relay stop)
P-12: self-locking (to a signal relay pull, give a signal relay to stop)
P-13: to signal, relay pull A seconds to stop automatically; during the delay trigger invalid
P-14: to signal, relay pull A seconds to stop automatically; trigger time in the delay time
P-15: to signal, relay pull A seconds to stop automatically; trigger time during delay
P-16: to signal, relay pull A seconds to stop automatically; trigger reset during delay
P-17: to the signal, the relay pull, the input signal is disconnected, start counting A seconds after the power, in the delay period to keep the signal output again, the timing stop
P-18: power, the relay immediately pull, delay A seconds after the power; until the next power
P-21: to the signal, delay A seconds after the relay pull
P-22: to the signal, more than A second, the relay pull, the signal disappears, the relay stops
P-23: signal disappears more than A second, the relay pulls, the signal disappears, the relay stops
P-24: When the signal is over A seconds, the relay pulls on and the signal disappears after more than A second, the relay stops
P-25: When the signal is over A seconds, the relay pulls in and the signal stops again after A seconds, the relay stops
P-26: Signal relay stops after A seconds, signal disappears Relay stops again after a second stop
P-27: detection of a pulse signal, the relay stopped; no pulse signal, the relay delay A seconds to pull; (signal or signal disappearance are regarded as no pulse signal)
P-28: After power-up, after a delay of 1 second, the relay pulls on until power is removed
P-31: After power-up, the relay pulls A seconds, turns off B seconds, infinite cycle;
P-32: signal, start P-31 infinite loop; signal disappears, the termination of the cycle
P-33: to give a signal, start P-31 infinite loop; give a signal to terminate the cycle
P-34: After power-up, after a second delay, the relay pulls and stops for B seconds
P-35: signal, delay A second, the relay pull, pull B seconds to stop
P-36: signal, more than A second, the relay pull, pull B seconds after the stop, the signal disappears, the clock is cleared
P-37: signal, relay pull A seconds to stop automatically, stop and then stop B seconds, in A + B time signal trigger invalid
P-38: Signal, relay pull A seconds to stop automatically, stop again after B seconds, again pull A seconds to stop automatically
7: key settings Description: power display "----" that entered the standby state;
Press the first time K1, (need more than 1 second to be effective to prevent false trigger) Display: P-11: K2 adjust the main mode, K3K4 adjustment function
Press the second time K1, the screen shows: A001: K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit)
Press the third time K1, the screen shows: B001: K2 and K3 adjust the second time B, K4 adjust the decimal point (time unit)
Press the fourth K1, display "----" that entered into standby mode
In standby mode, press K4, you can permanently turn off / on the display, switch low power mode
8: Decimal point time unit Description:
X.XX decimal point in the hundred, timing range: 0.01 seconds to 9.99 seconds
XX.X decimal point in the ten, timing range: 0.1 seconds to 99.9 seconds
XXX no decimal point, timing range: 1 second to 999 seconds
XXX. Decimal points in the bit, timing range: 1 minute to 999 minutes